Geosense In-place Inclinometer

Geosense hellende In-place Inclinometer (IPI) er designet for å måle sideveis bevegelse på nedstrømssiden av betongoverflater ved dammer eller andre hellende konstruksjoner.

  • Monteres i foringsrør som plasseres i et borehull, eller festes til en struktur
  • Benytter MEMS sensorer innkapslet i en rustfri stålkonstruksjon
  • Uni-aksiale og bi-aksiale alternativer

Description

Geosense/RST Inclined In-place inclinometers (IPI) are used primarily for monitoring the downstream concrete face of rock filled dams or any other inclined application. They are installed within inclinometer casing which is either placed in a borehole, concreted in or attached to a structure.

They consist of a series of wheeled sensors placed at various depths within the casing which are connected together with extension rods. Each sensor has specially designed connectors which allow them to move independently to each other without influence from the sensors above or below.

This provides a profile of displacement over the complete length of the installation and the extension rod lengths can be varied to suit individual gauge length requirements. Sensors can also be concentrated in areas where movement is expected.

In-place inclinometers are typically used for safety critical applications where “real time” monitoring and early warning is required in order to protect life and valuable assets. They are easy to automate using data acquisition systems and GeoAxiom Vista software.

Description
  • Range: ±15° from 45° (other ranges available on request)
  • Axis: Uniaxial and biaxial
  • Output: RS-485 digital BUS
  • Resolution: ±2 arc sec (±0,01 mm/min)
  • Non linearity: ±0.0125% FS (0,03 mm/min) (±0,002°)
  • Sensor type: MEMS (Micro-Electro-Mechanical-Systems)
  • Sensor dimensions: 500 mm length x 32 mm Ø
  • Sensor rating: IP68 (12 bar)
  • Operating temperature: -40 to +85°C
  • Casing size: 70-85 mm (others available on request)

Sensors
  • Standard sensor: 70 to 85 mm casing
  • Bottom sensor: 70 to 85 mm casing
  • Cable: To suit gauge length

Extension Rods
  • Gauge length (rod + sensor): 1,0, 1,5, 2,0, 2,5, 3,0 m
  • Rod length: 0,5, 1,0, 1,5, 2,0, 2,5 m

Support
  • Top hanger: For 70 or 85 mm casing
  • Wire hanger extension: Variable length
  • Top wheel assembly: For 70 or 85 mm casing

Materials
  • Sensor housing: Stainless steel
  • Extension rods: Stainless steel
  • Cable type: 2 twisted pair, braided, PUR sheath
  • Cable diameter: 5,6 mm

  • Number of installations
  • Depth of installations
  • Sensor spacing per installation
  • Casing diameter
  • Safety support rope
  • Dead end pulley

Nylig Sett