Your shopping cart is empty.

  • EnglishNorwegian

Geosense Tunnelprofil Overvåkingssystem

Geosense tunnelprofil-overvåkingssystem inneholder en rekke koblede stag som er festet til tunnelveggen for å overvåke deformasjon. Dataloggingssystem og programvare er tilgjengelig for sanntidsovervåkning av forskyvning og automatisk generering av grafiske presentasjoner.

  • Designet for å ikke forstyrre trafikken gjennom tunnelen
  • Utviklet spesielt for tilpasning til individuelle bruksområder
  • Direkte måling av forskyvning med nøyaktighet opptil 0,06 mm

Description

The Tunnel Profile Monitoring System is a series of linked rods, fixed to the tunnel wall, to monitor deformation. A data logging system and related software is available to provide near real time displacement and generate a graphical representation of tunnel performance.

A system of linked arms is affixed to the tunnel wall. Each arm is fitted with a high accuracy displacement sensor and precision tilt meter. Spatial displacement of the pins and arms results in changed tilt and displacement readings. The data logger system automatically collects the data and transmits it to a computer. The computer then analyses the data and calculates the displacement profile for presentation.

The system is available in either open or closed loop configurations. The closed loop method is analogous to conventional closed end survey techniques, while the open loop must be referenced to a known location.

  • Range: ±15° (other ranges upon request)
  • Resolution: ±2 arc sec. (±0,00006°) (0,01 mm/m)
  • Non-linearity: ±0,0125% FS (±0,002°) (0,03 mm/m)
  • Repeatability: ±0,0125% FS (±0,002°) (0,03 mm/m)
  • Sensor: MEMS (Micro-Electro-Mechanical Systems) Accelerometer, Digital Bus
  • Operating temperature: -40 to 85°C

Mechanical Displacement Sensor
  • Total mechanical travel: 25 mm
  • Shock: 50g, 11 ms half sine
  • Vibration: 20g rms 5 Hz to 2 KHz
  • Life: One billion dither operations

Electrical Displacement Sensor
  • Independent linearity: 0,25%
  • Operating temperature: -40 to 80°C
  • Resolution: Infinite
  • Accuracy: 0,06 mm


  • Tilt/displacement sensor assembly
  • Extension tube
  • Electrical cable sensor to logger
  • Reference pin comes with tape extensometer connector
  • Data logger system
  • GeoAxiom software
  • Manual


The following information will assist in product selection:
  • Detailed cross sectional drawing of each instrumented segment
  • Plain layout of instrumented segments and readout location
  • Open or closed loop system